Whatman Anotop 10 and 25 IC syringe filters from Cytiva's business are designed for efficient filtration prior to ion chromatography. Each batch is certified for low levels of anion leaching in ion chromatography (IC) filtration Filters large particulates, extending column life and increasing peak resolution Narrow pore size distribution and capillary pore structure for consistent results from a syringe filter Anotop for ion chromatography analysis Ion chromatography analysis often benefits from filtration as a sample preparation step. When done correctly, filtration can remove particles that might otherwise cause unwanted peaks or damage the chromatography column. Therefore, an ion exchange chromatography method should include a high-quality syringe filter. Cytiva's Anotop IC syringe filters have an aluminum-based Anopore membrane that minimizes anion leaching during ion chromatography filtration. Leaching is validated at 10−30 ppb for major anions such as fluoride, chloride, bromide, sulfate, nitrite, and nitrate (see product data). Aluminum-based Anotop syringe filters Anotop syringe filters are a versatile solution for most organic solvents and aqueous samples. Aluminum-based Anopore membranes are inorganic and designed to be inert and function in wide temperature ranges.
Read more >
119136
Anotop-IC
Media/Uploads/tn_30441_50054.jpg
Anotop Syringe Filter IC
Anotop Syringe Filter IC
Whatman Anotop 10 and 25 IC syringe filters from Cytiva's business are designed for efficient filtration prior to ion chromatography.</br> </br> Each batch is certified for low levels of anion leaching in ion chromatography (IC) filtration</br> Filters large particulates, extending column life and increasing peak resolution</br> Narrow pore size distribution and capillary pore structure for consistent results from a syringe filter</br> Anotop for ion chromatography analysis</br> Ion chromatography analysis often benefits from filtration as a sample preparation step. When done correctly, filtration can remove particles that might otherwise cause unwanted peaks or damage the chromatography column. Therefore, an ion exchange chromatography method should include a high-quality syringe filter.</br> </br> Cytiva's Anotop IC syringe filters have an aluminum-based Anopore membrane that minimizes anion leaching during ion chromatography filtration. Leaching is validated at 10−30 ppb for major anions such as fluoride, chloride, bromide, sulfate, nitrite, and nitrate (see product data).</br> </br> Aluminum-based Anotop syringe filters</br> Anotop syringe filters are a versatile solution for most organic solvents and aqueous samples. Aluminum-based Anopore membranes are inorganic and designed to be inert and function in wide temperature ranges.
17020.35
14547.31
page_28925
0
0
0